EVE PI Templates
Complete set of PI templates for EVE Online. The design strategy is to mine your P0 and tier it up to P1. Then take your P1 and ship it to P2/P3/P4 factories to efficiently produce PI with the least amount of headache as possible. You will find there isn't a mining template for every planets for every type. This is expected as CCP designed the system to auto switch the planet specific structures to the planet your trying to place the template on. Barring the minable material is available on said planet.
Screenshots from left to right.
00 Miners + P1 Factories (All Planets), Lowsec Miners + P1 Factories (All Planets)
P2/P3 Factories (All Planets), P4 Factories (Barren/Temperate Planets)
Future Plans
- P0 -> P2 Mining Variant
How to use these templates.
- Navigate to
/users/<user>/Documents/PlanetaryInteractionTemplates - Unzip and paste all json files in the folder above.
- Refresh your templates menu in game.
Skill Recommendations
| Skill Names | Miner | Factory |
|---|---|---|
| Command Center Upgrades | V | V |
| Interplanetary Consolidation | IV | V |
| Planetology | V | 0 |
| Advanced Planetology | IV | 0 |
| Total SP | 2,199,295 | 2,048,000 |
Best Estimate Template PG and CPU Usage
| Level | CPU | PG |
|---|---|---|
| 0 | 1675 | 6000 |
| 1 | 7057 | 9000 |
| 2 | 12136 | 12000 |
| 3 | 17215 | 15000 |
| 4 | 21315 | 17000 |
| 5 | 25415 | 19000 |
| Miner + P1 Template | 7x Links | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
WARNING Based on the numbers above, with CCU5, x16 Extractor heads, the mining template will be PG overloaded on planets larger than 15k. To use this template on larger planets or with CCU4, reduce your extractor head count.
| P2/P3 Factory | 1 Factory 12x Links | 2 Factory 24x Links | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
WARNING Based on the numbers above, with CCU5, 2 factories on 1 planet, your command center will be overloaded on planets with a radius large than 12,500 km. Remove factories to accommodate larger planets.
| P4 Factory | 1 Factory 8x Links | 2 Factory 16x Links | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
Factory - Max Input/Outputs
1 Factory requires 3000 units of P0 every 30 minutes to then output 20 units of P1
| Factories | Max Input Per Day | Max Output Per Day |
|---|---|---|
| 1 | 144,000 | 960 |
| 2 | 288,000 | 1,920 |
| 3 | 432,000 | 2,880 |
| 4 | 576,000 | 3,840 |
| 5 | 720,000 | 4,800 |
| 6 | 864,000 | 5,760 |
| 7 | 1,008,000 | 6,720 |
| 8 | 1,152,000 | 7,680 |
| 9 | 1,296,000 | 8,640 |
| 10 | 1,440,000 | 9,600 |
| 11 | 1,584,000 | 10,560 |
| 12 | 1,728,000 | 11,520 |
| 13 | 1,872,000 | 12,480 |
| 14 | 2,016,000 | 13,440 |
| 15 | 2,160,000 | 14,400 |
| 16 | 2,304,000 | 15,360 |
Miner info based on this table
- To keep your LS Miners running 24/7, your 2 extractors need to produce 576,000 P0 per day
- To keep your 00 Miners running 24/7, your 1 extractor needs to produce 1,152,000 P0 per day.
- Your storage unit can only hold 2,400,000 units of P0 at any given time
FAQ/Troubleshooting
- You will notice that the factories will be specified as Barren only. You can indeed use these on other planets, when you apply the template, the system will auto convert the factories to the planet specific types needed.
- The json files are touchy and can be corrupted easily. Edit them at your own risk and make backups.
- ALL templates will be available on ALL toons as long as they are in the folder above.
- Yes all routes are configured. Drop your PI in the starport and your factories turn on. WOOT WOOT!
- PI takes into account planet radius which effect link CPU/PG usage. View the tables I created above to get a best estimate of what your going to use on what size of planet.
- P2/P3 factories can be used on any planet, Gas planets are not recommended due to their size, but it can be done in a pinch.
- P4 factories can only be used on Barren and Temperate planets.
- You can place 2 factories on each planet with CCU V.
- If you would like to use these templates with lower CCU, you will need to edit the value
"CmdCtrLv": 5,in the json to the CCU value of your toon. Save and refresh your templates in game and they will be updated. - When using the mining templates you will find that the routes out of the extractors to the storage unit are missing. The is expected behavior because of the way CCP designed the system. You will need to set your extractor heads and then create your P0 routes back to the storage unit. No other user intervention should be required. https://github.com/DalShooth/EVE_PI_Templates/issues/2
- 00 Miners can be used in Lowsec, however you may find that you do not produce enough P0 to keep your P1 Factories running 24/7.